Numerical Simulations of Bromsulphthalein Test for Human Liver |
|
PP: 75-79 |
|
Author(s) |
|
A. A. M. Arafa,
I. M. Hanafy,
M. I. Gouda,
|
|
Abstract |
|
In this paper, we introduce the model of Bromsulphthalein (BSP) test whose components are BSP in blood, BSP in liver and
BSP in bile with fractional order. Generalized Euler method (GEM) is performed to solve the problem. We compare fractional results
and integer results with clinical data. The results show that the fractional order is closer than clinical data than standard model. |
|
|
 |
|
|